536300-02

ECN 225 2048 03S17-7V

Please choose an option:

Repair

Product Reconditioning*
Availability: service available
Delivery time: on inquiry
Price: on inquiry

express repair*
Availability: service available
Delivery time: on inquiry
Price: on inquiry

Cleaning & inspection**
Availability: service available
Delivery time: on inquiry
Price: on inquiry

Exchange

Reconditioned exchange part*
Availability: on inquiry
Delivery time: on inquiry
Price: on inquiry

Sales

Reconditioned replacement parts*
Availability: on inquiry
Delivery time: on inquiry
Price: on inquiry

New exchange part*
Availability: on inquiry
Delivery time: on inquiry
Price: on inquiry
Part number ID 536300-02
Product version Angle encoder with integral bearing
Name ECN
Model 225
Measuring standard DIADUR graduation on glass disk
Measuring method absolute (singleturn)
System accuracy ± 10"
Maximum position error per signal period ± 5"
Mechanical device version Hollow shaft with mounted stator coupling
Shaft type Hollow through shaft
Shaft diameter 50 mm
Flange version Flange with 76 mm width across flats, 72 mm bearing hole
Interface EnDat 2.2
Ordering designation EnDat02
Positions per revolution 33554432 (25 bit)
Electrical permissible speed = 3000 min?¹
Clock frequency = 2 MHz
Calculation time tcal 5 µs
Incremental signals 1 Vpp
Output signals per revolution 2048
Cutoff frequency (-3 dB) = 200 kHz
Power supply DC 3.6 V ... 5.25 V
Total current without load = 200 mA
Connecting direction Cable outlet for axial and radial use
Cable type PUR Ø 6.0 mm
Cable length 1 m
Electrical connection Coupling M23, male, 17-pin
Permissible cable length (with HEIDENHAIN cable) = 150 m
Mechanical permissible speed = 3000 min?¹
Starting torque at 20 °C = 0.15 Nm
Moment of inertia of the rotor (shaft) 0.000215 kgm²
Permissible axial motion of measured shaft ± 0.1 mm
Natural frequency = 1000 Hz
Vibration 55 Hz to 2000 Hz (EN 60068-2-6) = 100 m/s²
Shock 6 ms (EN 60068-2-27) = 1000 m/s²
Maximum operating temperature = +70 °C
Min. operating temperature (moving cable) = -10 °C
Min. operating temperature (stationary cable) = -20 °C
Degree of protection IP 64 (EN 60529)
Mass 0.8 kg
Add selected items to request list
Go to request basket
Go to request basket

* 24-month warranty on new parts, product-overhauling repairs and product-overhauled spare and replacement parts. We not only carry out our preventive measures for product-overhauling repairs, exchange and spare parts sales, but also extensively test each electronic assembly for function and load. In addition, we use original and safety-compliant components and thus guarantee the safety of the modules used in accordance with the standards of the Machinery Directive 2006/42 / EC.